TS-EMF EMF测试解决方案
TS-EMF EMF测试解决方案

TS-EMF EMF测试解决方案

主要特点

  • EMF频谱测量
  • 精确测量复杂场景和射频信号
  • 频率范围从9 kHz至6 GHz,由各向同性天线覆盖
  • 与方向和极化无关的各向同性天线探测场
  • 可与Rohde&Schwarz频谱分析仪R&S®FSH和R&S®FPH组合使用

描述

结合Rohde&Schwarz频谱分析仪,R&S®EMF测量系统检测环境中的高频电磁场(EMF)。各向同性天线允许在现场对发射进行简单而精确的评估。

根据国家和国际标准测量EMF辐射,为确保发射机系统符合适用限值以及向公众传达这一点提供了基础。关键标准是精确、易于现场测量。

R&S®FSH与R&S®TS-EMF支持FSH-K105选项,还支持自动EMF测量,以及相关选项,还可解码3G和4G信号。

简要规格

Isotropic 天线 R&S®TSEMF-B3 R&S®TSEMF-B1 R&S®TSEMF-B2
Measurement principle isotropic reception due to orthogonally arranged antenna elements that are electronically switched
频率范围 9 kHz to 200 MHz 30 MHz to 3 GHz 700 MHz to 6 GHz
灵敏度/最小场强 approx. 1 mV/m
最大场强 ≥100 V/m ≥230 V/m ≥230 V/m
Isotropy 各向同性 ≤ ±1.37 dB ≤ ±2.1 dB,
±1.0 dB (f = 900 MHz),
±1.7 dB (f = 1800 MHz)
≤ ±2.5 dB (0.6 GHz to 2 GHz),
≤ ±2.2 dB (2 GHz to 3.6 GHz),
≤ ±3.0 dB (3.6 GHz to 6 GHz)
Mechanical design radome protection against mechanical damage and environmental hazards
Antenna factor individual calibration data, saved on USB dongle and/or CD
Axis switching RF solid state switch
Connecting cables direct connection to spectrum analyzer (extension cable (length: 8 m) see accessories) integrated cable (length: 2 m) ferritebeaded (extension cable (length: 8 m) see accessories) integrated cable (length: 2 m, extension cable (length: 8 m) see accessories))
RF connector N male
Connector, control line 7-pin connector (binder) for direct connection to R&S®FSH power sensor port, adapter cable for connection to notebook or spectrum analyzer with USB output
Tripod adapter ¼-” thread, quick connector for antenna
Requirements for notebook (not supplied) MS Windows7 or Windows8 operating system, free hard disk space: min. 5 Gbyte
display resolution: min. 800 × 600 pixel, two USB interfaces
interface to test instrument (depending on analyzer: GPIB, LAN, USB or FireWire)
recommended application: Excel 2007, 2010, 2013
Equipment supplied isotropic sensor with connecting cable operator’s guide for R&S®RFEX and R&S®RFEX-Fast measurement software (on CD), tripod adapter, USB adapter cable, transit case (R&S®TS-EMF with at least one isotropic antenna)
Expanded measurement uncertainty R&S®TS-EMF with R&S®FSH (95 % confidence level (k = 2)) ≤ ±2.5 dB ≤ ±3.3 dB,
±2.3 dB at 0.9 GHz,
±2.9 dB at 1.8 GHz
≤ ±3.1 dB (0.7 GHz to 1 GHz),
≤ ±3.3 dB at (1 GHz to 3.6 GHz),
≤ ±3.7 dB at (3.6 GHz to 6 GHz)
Expanded measurement uncertainty R&S®TS-EMF with R&S®FSL (95 % confidence level (k = 2)) ≤ ±2.4 dB ≤ ±3.2 dB,
±2.2 dB at 0.9 GHz,
±2.9 dB at 1.8 GHz
≤ ±2.9 dB (0.7 GHz to 1 GHz),
≤ ±3.2 dB at (1 GHz to 3.6 GHz),
≤ ±3.6 dB at (3.6 GHz to 6 GHz)
Power supply via spectrum analyzer or laptop
Ambient conditions –10 °C to +50 °C, safety class IP54 (see user manual for details)
Weight (incl. cable) 0.85 kg
1.87 lb
1.3 kg
2.87 lb
0.95 kg
2.09 lb
Dimensions (L × ∅) 550 mm × 146 mm
21.7 in. × 5.75 in.
475 mm × 170 mm
18.7 in. × 6.69 in.
415 mm × 87 mm
16.3 in. × 3.43 in.