﻿{"id":3663,"date":"2021-04-27T11:27:09","date_gmt":"2021-04-27T03:27:09","guid":{"rendered":"http:\/\/www.comtest.cn\/?post_type=product&#038;p=3663"},"modified":"2021-04-27T11:27:11","modified_gmt":"2021-04-27T03:27:11","slug":"eny81","status":"publish","type":"product","link":"http:\/\/www.comtest.com.cn\/?product=eny81","title":{"rendered":"ENY81\u8026\u5408\u7f51\u7edc"},"content":{"rendered":"<p>\u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf<\/p>\n<h2>\u7b80\u8981\u89c4\u683c<\/h2>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<thead>\n<tr>\n<td colspan=\"3\"><strong>\u9891\u7387\u8303\u56f4<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Radio disturbance measurements<\/td>\n<td>R&amp;S<sup>\u00ae<\/sup>ENY81<\/td>\n<td>150\u00a0kHz to 30\u00a0MHz<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td colspan=\"3\"><strong>Asymmetrical impedance<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Impedance<\/td>\n<td>R&amp;S<sup>\u00ae<\/sup>ENY81: 0.15\u00a0MHz to 30\u00a0MHz<\/td>\n<td>150 \u03a9 \u00b1 20 \u03a9<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td>Phase angle<\/td>\n<td>0.15\u00a0MHz to 30\u00a0MHz<\/td>\n<td>0\u00b0 \u00b1 20\u00b0<\/td>\n<\/tr>\n<tr>\n<td><strong>Voltage division factor in asymmetrical circuit<\/strong><\/td>\n<td>150\u00a0kHz to 30\u00a0MHz<\/td>\n<td>typ. 10\u00a0dB \u00b1 1\u00a0dB (calibration data supplied)<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>&gt; 30\u00a0MHz to 80\u00a0MHz<\/td>\n<td>typ. 10\u00a0dB \u00b1 2\u00a0dB<\/td>\n<\/tr>\n<tr>\n<td><strong>\u5e26\u5bbd<\/strong><\/td>\n<td>3\u00a0dB<\/td>\n<td>&gt;100\u00a0MHz (for 100\u00a0\u03a9 source and load impedances<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td colspan=\"3\"><strong>Longitudinal conversion loss (LCL)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>55\u00a0dB adapter<\/td>\n<td>LCL (dB)<\/td>\n<td>55\u00a0dB \u2013 10 log (1 + (f\/5)<sup>2<\/sup>)\u00a0dB<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>tolerance<\/td>\n<td>\u00b13\u00a0dB, for 0.15\u00a0MHz \u2264 f \u2264 30\u00a0MHz<\/td>\n<\/tr>\n<tr>\n<td>65 dB adapter<\/td>\n<td>LCL (dB)<\/td>\n<td>65\u00a0dB \u2013 10\u00a0log (1 + (f\/5)<sup>2<\/sup>)\u00a0dB<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>tolerance<\/td>\n<td>\u00b13\u00a0dB, for f &lt; 2\u00a0MHz, \u20133\/+4.5\u00a0dB, for 2\u00a0MHz \u2264 f \u2264 30\u00a0MHz<\/td>\n<\/tr>\n<tr>\n<td><strong>Decoupling attenuation<\/strong><\/td>\n<td>150\u00a0kHz to 1.5\u00a0MHz<\/td>\n<td>&gt; 35\u00a0dB to 55\u00a0dB (increases linearly with logarithm of frequency)<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>1.5\u00a0MHz to 30\u00a0MHz<\/td>\n<td>&gt; 55\u00a0dB<\/td>\n<\/tr>\n<tr>\n<td><strong>Crosstalk (PSELFEXT, EUT\/AE)<\/strong><\/td>\n<td>1\u00a0MHz to 100\u00a0MHz<\/td>\n<td>\u2265 61\u00a0dB to \u2265 21\u00a0dB (increases linearly with logarithm of frequency)<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td colspan=\"3\"><strong>Maximum values<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Max. permissible RF input voltage<\/td>\n<td><\/td>\n<td>&lt; 15\u00a0V<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td>Max. permissible DC voltage between line and ground<\/td>\n<td><\/td>\n<td>100\u00a0V<\/td>\n<\/tr>\n<tr>\n<td>Max. permissible AC voltage between line and ground<\/td>\n<td><\/td>\n<td>63\u00a0V<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td>Max. permissible DC current<\/td>\n<td><\/td>\n<td>600\u00a0mA (current on each individual wire of one pair or on different pairs)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>Connectors<\/strong><\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td>Output to test receiver\/input from signal generator<\/td>\n<td><\/td>\n<td>BNC female<\/td>\n<\/tr>\n<tr>\n<td>Connectors for EUT and AE<\/td>\n<td><\/td>\n<td>adapter with 1 mm connectors and RJ-11 or RJ\u201145 connectors<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td colspan=\"3\"><strong>General data<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>operating temperature<\/td>\n<td>+5 \u00b0C to +40 \u00b0C<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>storage temperature<\/td>\n<td>\u201320 \u00b0C to +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Overall dimensions (B \u00d7 H \u00d7 T)<\/td>\n<td>base unit<\/td>\n<td>105 mm \u00d7 65 mm \u00d7 110 mm (4.13 in \u00d7 2.56 in \u00d7 4.33 in)<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>base unit with adapters<\/td>\n<td>105 mm \u00d7 65 mm \u00d7 190 mm (4.13 in \u00d7 2.56 in \u00d7 7.48 in)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>base unit with adapters<\/td>\n<td>520 g (1.15 lb)<\/td>\n<\/tr>\n<tr class=\"bkgr\">\n<td><\/td>\n<td>R&amp;S<sup>\u00ae<\/sup>ENY81 case with basic adapter set<\/td>\n<td>1640 g (3.62 lb)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>\u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf<\/p>\n","protected":false},"featured_media":3658,"template":"","meta":[],"product_brand":[],"product_cat":[128,70],"product_tag":[],"class_list":{"0":"post-3663","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rs","7":"product_cat-emc_vnetwork","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\r\n<title>ENY81\u8026\u5408\u7f51\u7edc - \u901a\u6d4b\u79d1\u6280<\/title>\r\n<meta name=\"description\" content=\"The R&amp;S\u00aeENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs. 8\u7ebf\u7f51\u7edc Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz) Compliance with CISPR 16-1-2 Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces High transmission bandwidth for wanted signal (100 MHz) \u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf\" \/>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"http:\/\/www.comtest.com.cn\/?product=eny81\" \/>\r\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"ENY81\u8026\u5408\u7f51\u7edc - \u901a\u6d4b\u79d1\u6280\" \/>\r\n<meta property=\"og:description\" content=\"The R&amp;S\u00aeENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs. 8\u7ebf\u7f51\u7edc Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz) Compliance with CISPR 16-1-2 Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces High transmission bandwidth for wanted signal (100 MHz) \u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf\" \/>\r\n<meta property=\"og:url\" content=\"http:\/\/www.comtest.com.cn\/?product=eny81\" \/>\r\n<meta property=\"og:site_name\" content=\"\u901a\u6d4b\u79d1\u6280\" \/>\r\n<meta property=\"article:modified_time\" content=\"2021-04-27T03:27:11+00:00\" \/>\r\n<meta property=\"og:image\" content=\"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg\" \/>\r\n\t<meta property=\"og:image:width\" content=\"618\" \/>\r\n\t<meta property=\"og:image:height\" content=\"330\" \/>\r\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 \u5206\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.comtest.com.cn\/?product=eny81\",\"url\":\"http:\/\/www.comtest.com.cn\/?product=eny81\",\"name\":\"ENY81\u8026\u5408\u7f51\u7edc - \u901a\u6d4b\u79d1\u6280\",\"isPartOf\":{\"@id\":\"http:\/\/www.comtest.com.cn\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/www.comtest.com.cn\/?product=eny81#primaryimage\"},\"image\":{\"@id\":\"http:\/\/www.comtest.com.cn\/?product=eny81#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg\",\"datePublished\":\"2021-04-27T03:27:09+00:00\",\"dateModified\":\"2021-04-27T03:27:11+00:00\",\"description\":\"The R&S\u00aeENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs. 8\u7ebf\u7f51\u7edc Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz) Compliance with CISPR 16-1-2 Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces High transmission bandwidth for wanted signal (100 MHz) \u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf\",\"breadcrumb\":{\"@id\":\"http:\/\/www.comtest.com.cn\/?product=eny81#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.comtest.com.cn\/?product=eny81\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.comtest.com.cn\/?product=eny81#primaryimage\",\"url\":\"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg\",\"contentUrl\":\"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg\",\"width\":618,\"height\":330},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.comtest.com.cn\/?product=eny81#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"http:\/\/www.comtest.cn\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4ea7\u54c1\u76ee\u5f55\",\"item\":\"http:\/\/www.comtest.com.cn\/?page_id=897\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ENY81\u8026\u5408\u7f51\u7edc\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.comtest.com.cn\/#website\",\"url\":\"http:\/\/www.comtest.com.cn\/\",\"name\":\"\u901a\u6d4b\u79d1\u6280\",\"description\":\"\u4e13\u4e1a\u6d4b\u8bd5\u7cfb\u7edf\u89e3\u51b3\u65b9\u6848\u63d0\u4f9b\u5546\",\"publisher\":{\"@id\":\"http:\/\/www.comtest.com.cn\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.comtest.com.cn\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"http:\/\/www.comtest.com.cn\/#organization\",\"name\":\"\u901a\u6d4b\u79d1\u6280\",\"url\":\"http:\/\/www.comtest.com.cn\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.comtest.com.cn\/#\/schema\/logo\/image\/\",\"url\":\"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2023\/04\/COMTESTNoRlogo-2.png\",\"contentUrl\":\"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2023\/04\/COMTESTNoRlogo-2.png\",\"width\":472,\"height\":165,\"caption\":\"\u901a\u6d4b\u79d1\u6280\"},\"image\":{\"@id\":\"http:\/\/www.comtest.com.cn\/#\/schema\/logo\/image\/\"}}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ENY81\u8026\u5408\u7f51\u7edc - \u901a\u6d4b\u79d1\u6280","description":"The R&S\u00aeENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs. 8\u7ebf\u7f51\u7edc Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz) Compliance with CISPR 16-1-2 Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces High transmission bandwidth for wanted signal (100 MHz) \u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.comtest.com.cn\/?product=eny81","og_locale":"zh_CN","og_type":"article","og_title":"ENY81\u8026\u5408\u7f51\u7edc - \u901a\u6d4b\u79d1\u6280","og_description":"The R&S\u00aeENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs. 8\u7ebf\u7f51\u7edc Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz) Compliance with CISPR 16-1-2 Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces High transmission bandwidth for wanted signal (100 MHz) \u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf","og_url":"http:\/\/www.comtest.com.cn\/?product=eny81","og_site_name":"\u901a\u6d4b\u79d1\u6280","article_modified_time":"2021-04-27T03:27:11+00:00","og_image":[{"width":618,"height":330,"url":"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"http:\/\/www.comtest.com.cn\/?product=eny81","url":"http:\/\/www.comtest.com.cn\/?product=eny81","name":"ENY81\u8026\u5408\u7f51\u7edc - \u901a\u6d4b\u79d1\u6280","isPartOf":{"@id":"http:\/\/www.comtest.com.cn\/#website"},"primaryImageOfPage":{"@id":"http:\/\/www.comtest.com.cn\/?product=eny81#primaryimage"},"image":{"@id":"http:\/\/www.comtest.com.cn\/?product=eny81#primaryimage"},"thumbnailUrl":"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg","datePublished":"2021-04-27T03:27:09+00:00","dateModified":"2021-04-27T03:27:11+00:00","description":"The R&S\u00aeENY81 coupling network has been designed to measure the asymmetrical (common-mode) disturbance voltage of unshielded, symmetrical telecommunications ports of EUTs. 8\u7ebf\u7f51\u7edc Radio disturbance measurements in line with CISPR 22: 2008 and EN 55022: 2010 or CISPR 32 and EN 55032 (150 kHz to 30 MHz) Compliance with CISPR 16-1-2 Adapter sets to meet standardized LCL requirements (55 dB and 65 dB) and to accommodate various telecommunications interfaces High transmission bandwidth for wanted signal (100 MHz) \u9488\u5bf9\u65e0\u5c4f\u853d\u3001\u5bf9\u79f0\u7535\u4fe1\u7aef\u53e3\u7684\u65e0\u7ebf\u7535\u5e72\u6270\u6d4b\u91cf","breadcrumb":{"@id":"http:\/\/www.comtest.com.cn\/?product=eny81#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.comtest.com.cn\/?product=eny81"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.comtest.com.cn\/?product=eny81#primaryimage","url":"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg","contentUrl":"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2021\/04\/ENY81_front_lightbox_landscape.jpg","width":618,"height":330},{"@type":"BreadcrumbList","@id":"http:\/\/www.comtest.com.cn\/?product=eny81#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"http:\/\/www.comtest.cn\/"},{"@type":"ListItem","position":2,"name":"\u4ea7\u54c1\u76ee\u5f55","item":"http:\/\/www.comtest.com.cn\/?page_id=897"},{"@type":"ListItem","position":3,"name":"ENY81\u8026\u5408\u7f51\u7edc"}]},{"@type":"WebSite","@id":"http:\/\/www.comtest.com.cn\/#website","url":"http:\/\/www.comtest.com.cn\/","name":"\u901a\u6d4b\u79d1\u6280","description":"\u4e13\u4e1a\u6d4b\u8bd5\u7cfb\u7edf\u89e3\u51b3\u65b9\u6848\u63d0\u4f9b\u5546","publisher":{"@id":"http:\/\/www.comtest.com.cn\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.comtest.com.cn\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"http:\/\/www.comtest.com.cn\/#organization","name":"\u901a\u6d4b\u79d1\u6280","url":"http:\/\/www.comtest.com.cn\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.comtest.com.cn\/#\/schema\/logo\/image\/","url":"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2023\/04\/COMTESTNoRlogo-2.png","contentUrl":"http:\/\/www.comtest.com.cn\/wp-content\/uploads\/2023\/04\/COMTESTNoRlogo-2.png","width":472,"height":165,"caption":"\u901a\u6d4b\u79d1\u6280"},"image":{"@id":"http:\/\/www.comtest.com.cn\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=\/wp\/v2\/product\/3663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=\/wp\/v2\/product\/3663\/revisions"}],"predecessor-version":[{"id":3664,"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=\/wp\/v2\/product\/3663\/revisions\/3664"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=\/wp\/v2\/media\/3658"}],"wp:attachment":[{"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3663"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=3663"},{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=3663"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/www.comtest.com.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=3663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}